Fire Alarm Cable Unshielded 300V FAS

FT4 CSA UL

 

Solid bare copper conductors, PVC insulation, Red PVC jacket FT-4 -20° C to 105° C, 300 Volts, CSA and UL Approved.

Applications:

PCS
Catalogue
Number
Conductor Wall Thickness Nominal
O.D.
(inches)
Total
Weight
(lbs/km)
Colour Code Chart
No. AWG
Size
Stranding Insulation
(inches)
Jacket
(inches)
FA22-06CBO 6 22 Solid .015 .030 .225 113 7
FA22-10CBO 10 22 Solid .015 .032 .275 173 7
FA22-15CBO 15 22 Solid .015 .032 .321 240 7
FA22-20CBO 20 22 Solid .015 .032 .360 307 7
FA22-30CBO 30 22 Solid .015 .040 .443 460 7
FA18-02CBO 2 18 Solid .015 .030 .209 90 7
FAP18-02CBO* 2 18 Solid .015 .030 .131 X .203 75 7
FA18-03CBO 3 18 Solid .015 .030 .224 120 7
FA18-04CBO 4 18 Solid .015 .030 .238 147 7
FA18-05CBO 5 18 Solid .015 .030 .255 173 7
FA18-06CBO 6 18 Solid .015 .032 .271 200 7
FA18-07CBO 7 18 Solid .015 .032 .289 219 7
FA18-08CBO 8 18 Solid .015 .032 .302 253 7
FA18-09CBO 9 18 Solid .015 .032 .316 273 7
FA18-10CBO 10 18 Solid .015 .032 .330 307 7
FA18-11CBO 11 18 Solid .015 .032 .340 324 7
FA18-15CBO 15 18 Solid .015 .040 .403 460 7
FA18-20CBO 20 18 Solid .015 .040 .454 593 7
FA18-21CBO 21 18 Solid .015 .040 .460 608 7
FA18-30CBO 30 18 Solid .015 .040 .535 842 7
FA18-50CBO 50 18 Solid .015 .048 .692 1,375 7
FAP16-02CBO* 2 16 Solid .015 .035 .156 X .240 110 7
FA16-02CBO 2 16 Solid .015 .035 .244 110 7
FA16-03CBO 3 16 Solid .015 .035 .254 147 7
FA16-04CBO 4 16 Solid .015 .035 .279 184 7
FA14-02CBO 2 14 Solid .020 .040 .302 170 7
FA14-03CBO 3 14 Solid .020 .040 .315 226 7
FA14-04CBO 4 14 Solid .020 .040 .343 285 7

FA12-02CBO

2 12 Solid .020 .040 .340 256 7

 

Aluminum or Steel Interlock Armour and Jacket available upon request.

* Flat or Parallel Construction

¶ Grey Jacket available upon request

 

Applications:

  • FAS 105: Fire Alarm & Signal Cable for interconnection of electrical devices within a security and fire protective signaling system.  The cables are intended for installation according to Section 32 of the Canadian Electrical Code Part 1 2002 Edition.
  • LVT: Class 2 circuit wiring for installation according to Section 16 of the CEC Part 1 2002 Edition.
  • FT1: For installation in buildings of combustible construction (excluding plenum areas) per the CEC PT-1 1998 Edition Rule 2-126 and the National Building Code 1995 Edition Article 3.1.4.3.
  • FT4: For installation in buildings of non-combustible construction and plenum areas in any building per the CEC Part 1 Rule 2-126 and the National Building Code 1995 Edition Articles 3.1.5.17 and 3.6.4.3.

Notes

  • Unless otherwise permitted by local electrical inspection authorities, Section 32 (CEC Part 1) requires that non-metallic sheathed fire alarm cables used in non-combustible buildings be installed in conduit or metal armour (32-102), regardless of an FT4 designation.  As a cost-effective alternative to metal conduit, Fire Alarm Cable is available with an interlock aluminum armour.
  • B.C. and Ontario do not permit the use of FT4 cables in plenums unless enclosed in non-combustible raceway, i.e., metal conduit, or interlock armour.